Quality Management
Inspection plans, in-process & final inspection, rejects, rework and parameter tolerances.
First Pass Yield
98.1%
0.4%
Reject Rate
1.2%
0.2%
Rework
0.7%
Inspections Today
186
Standards & Plans:
Inspections & Audits:
Non-Conformance & Rework:
Inspection Parameters & Tolerances
Target specifications, upper/lower limits, and measurement tools
| ID | Parameter | Target | Min | Max | Unit | Method | Result | Actions |
|---|---|---|---|---|---|---|---|---|
| P-01 | Length | 120 | 119.9 | 120.1 | mm | Vernier Caliper | Pass | |
| P-02 | Width | 45 | 44.92 | 45.08 | mm | Micrometer | Pass | |
| P-03 | Diameter | 12 | 11.98 | 12.02 | mm | Bore Gauge | Pass | |
| P-04 | Surface Finish | 1.6 | 0.8 | 3.2 | Ra μm | Surface Profilometer | Pass | |
| P-05 | Weight | 480 | 475 | 485 | g | Electronic Balance | Fail | |
| P-06 | Hardness | 58 | 55 | 62 | HRC | Rockwell Tester | Pass | |
| P-07 | Visual Inspection | 0 | 0 | 0 | defects | Visual | Pass | |
| P-08 | Color | 0 | 0 | 0 | ΔE | Spectrophotometer | Pass | |
| P-09 | Thread Quality | 0 | 0 | 0 | Go/NoGo | Thread Gauge | Pass | |
| P-10 | Hole Diameter | 8 | 7.98 | 8.02 | mm | Pin Gauge | Pass | |
| P-11 | Burr Check | 0 | 0 | 0 | mm | Visual + Feeler | Pass | |
| P-12 | Flatness | 0 | 0 | 0.05 | mm | Dial Indicator | Pass |